Z-RAM Ultra 3 repair
Updated with the new photographs of the failure, repair, and validation process.
Figure 1
General view of the installed Z-RAM Ultra 3.
- Initial boot symptom: horizontal bars similar to those seen when the CPU is absent from the computer.
- All chips on the board had already been removed and their contacts cleaned.
Figura 2
Close-up of the transistor area and recovery jumper.
- Enlarged view of the transistor affected by corrosion and the repair area.
- The blue jumper runs from the center leg of the transistor to its solder point on the underside of the board (the solder point on the upper side was corroded and weakened).
- The battery was removed, even after installing a new Varta battery. The battery presents more risk than benefit due to the possibility of a short circuit or future leakage. The Z-RAM Ultra 3 does not require the battery for normal operation, only for the clock and date/time retention.
Figure 3
Intermediate sockets used to correct contact issues.
Figure 4
Bottom view of the adapters
Figure 5
Details of the mechanical adaptation.
Figuras 6 e 7
Official Applied Engineering diagnostic tool status completed successfully. Card Passed.
Additional result after 10 hours of continuous testing: 4,121 passes.
Note: The jumper located on the underside of the board was not photographed in order to avoid further disassembly of the Apple IIc after completion and validation of the repair.
| Attachment | Size |
|---|---|
| 1.27 MB |
- jhyppolito's blog