I'm having a problem with the 4116 RAM, so I'm asking. Is it possible to run the AppleII Europlus with 16kB RAM in just one bank? If so, which bank on the PCB should it be in?

Offline
Last seen: 15 hours 57 min ago
Joined: Apr 26 2016 - 08:36
Posts: 885
Yes.  You can get to the

Yes.  You can get to the Applesoft prompt and the Machine language monitor with just 16K installed.

The lower 16K is Row "C".

You should also be able to load small programs via the cassette ports with 16K, but DOS requires all 48K to load.

S.Elliott's picture
Offline
Last seen: 2 hours 56 min ago
Joined: Jun 23 2022 - 16:26
Posts: 341
DOS System Master requires 16K
baldrick wrote:

You should also be able to load small programs via the cassette ports with 16K, but DOS requires all 48K to load.

 

That's a fair rule-of-thumb, but if someone is actually testing a system with less than 48K then a more precise definition is warranted:

 

tl;dr summary: DOS MASTER DISKS will boot on any memory size strictly-larger than 12K.  Most user-formatted diskettes are not MASTER DISKS, so they require the same amount of motherboard memory as the computer that initialized the diskette, commonly 48K.

 

Longer explanation DOS 3.X memory requirements: There are two types of DOS disks, with slightly different memory requirements.

  • MASTER DISKS boot on any system with at least 16K of memory, and DOS configures itself to match the memory configuration of whatever computer it's booted on.  There won't be much memory available if you boot DOS on a 16K system, and it will often give "OUT OF MEMORY" errors when trying to load a program, but it it's a master disk then it will at least boot to a command prompt.  All Apple-supplied DOS diskettes were master disks.
  • non-MASTER diskettes boot as the same memory configuration require the same amount of memory as the computer that was used to create them.  For example, if a diskette was initialized on a 36K computer, then it will always boot into a 36K memory configuration -- it just won't work on a smaller memory size, and if you boot it into a larger memory size, it won't benefit ffom the addditional memory.  A non-MASTER diskette can be converted to MASTER diskettes by a program ("MASTER CREATE") on the DOS SYSTEM MASTER diskette.
Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
Thank you for the explanation

Thank you for the explanation regarding the DOS system.It appears, however, that I have a different problem.As it turns out, my Apple II Europlus is death.I checked all the TTL integrated circuits using a logic chip tester, and they all seem to be functional.Using an oscilloscope, I determined that the 14 MHz signal is not being generated correctly.It seems that the voltage parameters of the 14 MHz clock signal do not meet the TTL standard.I looked under the quartz crystal resonator and discovered that one of the capacitors is damaged (ruptured).Interestingly, the crystal oscillator circuit seems to be running; I compared both transistors against new ones I purchased online, and they appear to be fine. The same applies to the resistors, and the 74S86 chip also seems to be working; nevertheless, the amplitude of the 14 MHz signal is outside the TTL range.Hence my question: what should the value of the capacitor in an Apple II Europlus be, and what should the amplitude of the 14 MHz signal be?Interestingly, the 7 MHz signal is being generated, but the TH1 and TH0 signals are not.

https://www.applefritter.com/files/2026/11/08/timing_generator_2.pdf

Offline
Last seen: 17 hours 5 min ago
Joined: Feb 27 2021 - 18:59
Posts: 933
The 74S86 XOR gate output on

The 74S86 XOR gate output on pin 8 is the buffered 14M clock at TTL levels, which are between 0 V and +3 V approximately. The crystal oscillator circuit which feeds it on pin 10 is not TTL (operates from +12 V) and probing it directly may disturb its oscillation because of the capacitance of the probe.

7M is output on pin 15 of 74S175, and ø0 on pin 7, ø1 on pin 6 of the same chip. The clock divider function relies on the other section of the XOR 74S86. If the counter never counts above 1 (0..1..0..1..0..1) then its pin 15 output will toggle but the higher outputs will be stuck.

The F-F inputs that change ø0, ø1 come from the RAM timing circuits 74LS153, 74LS195.

Offline
Last seen: 3 hours 38 min ago
Joined: Jun 18 2010 - 13:54
Posts: 900
If the 7M signal is OK, the

If the 7M signal is OK, then 14M must be OK as well. If PH0 and PH1 are not working, I'd check ICs C1 and C2. Also make sure Ph0 is not shorted out somewhere else.

Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
This is the signal on pin 8

This is the signal on pin 8 of 74s86:

 

Its amplitude appears to be between 1 V and 2.4 V. This is not fully compliant with the TTL standard; the 7 MHz signal is generated independently of PH0 and PH1.All TTL circuits appear to be working.If the PCB contains only the oscillator circuit and the 74S86 IC, the signal level does not change.

I wonder what could be causing this?

Offline
Last seen: 3 hours 38 min ago
Joined: Jun 18 2010 - 13:54
Posts: 900
gregor wrote:This is the
gregor wrote:

This is the signal on pin 8 of 74s86:

 What scope and probe are you using? Specifically, what is it's bandwith?

CVT
CVT's picture
Offline
Last seen: 1 day 10 hours ago
Joined: Aug 9 2022 - 00:48
Posts: 1662
gregor wrote:This is the
gregor wrote:

This is the signal on pin 8 of 74s86:

...

 

Remove the 74S86 from its socket and attach the probe of your oscilloscope to pin 10 of the empty socket. This is what you should be seeing if the generator feeding the 74S86 chip is working properly:

 

Offline
Last seen: 1 week 9 hours ago
Joined: Apr 27 2025 - 09:53
Posts: 126
@CVT,  jeffmazur is right.

@CVT,  jeffmazur is right. This is a vintage oscilloscope with about 10 MHz (or lower) bandwidth. There is no problem with the TTL chips; your advice for chip removal is wrong. Using a vintage scope like this for Apple II maintenance is perfectly fine, rather than investing in contemporary, expensive instruments.

CVT
CVT's picture
Offline
Last seen: 1 day 10 hours ago
Joined: Aug 9 2022 - 00:48
Posts: 1662
transwarp2 wrote:@CVT, 
transwarp2 wrote:

@CVT,  jeffmazur is right. This is a vintage oscilloscope with about 10 MHz (or lower) bandwidth. There is no problem with the TTL chips; your advice for chip removal is wrong. Using a vintage scope like this for Apple II maintenance is perfectly fine, rather than investing in contemporary, expensive instruments.

 

Where did I say that he should invest in another oscilloscope?? Looks like NI can hallucinate just like AI! ;)

 

It's hard to tell form the picture, but if the oscilloscope is B&K Precision 1530, it should have more than enough bandwidth to see the 14 MHz sine wave.

Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
This is an oscilloscope with

This is an oscilloscope with a 35 MHz bandwidth.The oscilloscope is in full working order.I have tested all the TTL integrated circuits using an XGecu T48 programmer – they are functional, at least in terms of their logic.Without the 74S86 chip, the signal amplitude is slightly lower.Furthermore, I should be detecting a signal with a frequency of approximately 2 MHz at the input (pin 5) of the 74S175 chip; instead, it remains in a constant high state.

Oscilloscope is TRIO 35MHz CS-1577A

CVT
CVT's picture
Offline
Last seen: 1 day 10 hours ago
Joined: Aug 9 2022 - 00:48
Posts: 1662
gregor wrote:This is an
gregor wrote:

This is an oscilloscope with a 35 MHz bandwidth.The oscilloscope is in full working order.I have tested all the TTL integrated circuits using an XGecu T48 programmer – they are functional, at least in terms of their logic.Without the 74S86 chip, the signal amplitude is slightly lower.Furthermore, I should be detecting a signal with a frequency of approximately 2 MHz at the input (pin 5) of the 74S175 chip; instead, it remains in a constant high state.

Oscilloscope is TRIO 35MHz CS-1577A

 

Makes sense, B&K Precision and TRIO were the same oscilloscopes in those days, just branded differently. Since you have a good enough oscilloscope for the task, take a look at Sams Computer Facts - Apple II, II Plus.pdf starting at the top of page 57 (PDF page numbering).

Offline
Last seen: 17 hours 5 min ago
Joined: Feb 27 2021 - 18:59
Posts: 933
Probe

The scope may have sufficient bandwidth, but it also depends on the probe. Using a 1X probe, for example, will severely limit the bandwidth of the system. The probe being used must also be calibrated to the scope's input impedance in order to work correctly.

When using a 10X probe together with a scope that isn't able to detect probe type, you need to manually convert the amplitudes on screen for the probe's attenuation factor. For example, 1 V peak-to-peak with a 10X probe is really 10 V peak-to-peak.

Offline
Last seen: 2 hours 16 min ago
Joined: May 31 2022 - 18:18
Posts: 379
Did you try a different 74S86

Did you try a different 74S86?

 

I didn't see it mentioned, but CVT will often do so, don't trust any chip tester. While they can test basic functionality that really means very little in real world conditions. And... this 14M signal... that's why it's got the S86 vs LS86. Looks like you have a DC offset in your signal (if the others about scope/probe/etc setups are correct) thats a concern for me.

 

But as other have mentioned, if you got a 7M signal suggests your 14M is fine and it's a measurment problem... I think I'd be looking elsewhere in the circuit. The "blown cap" in the clock gen is strange and... for proper frequency that's gonna need to be pretty tight on tolerance (but you didn't say exactly which cap)

 

Offline
Last seen: 1 week 9 hours ago
Joined: Apr 27 2025 - 09:53
Posts: 126
CVT wrote:Since you have a
CVT wrote:
Since you have a good enough oscilloscope for the task

I see they don't. Yes, robespierre is right -- the probe, the leads are part of the measuring device, and they can limit the bandwidth. Let the OP measure another known 14 MHz source with the same probe and oscilloscope.

 

 

CVT
CVT's picture
Offline
Last seen: 1 day 10 hours ago
Joined: Aug 9 2022 - 00:48
Posts: 1662
transwarp2 wrote:CVT wrote
transwarp2 wrote:
CVT wrote:
Since you have a good enough oscilloscope for the task

I see they don't. Yes, robespierre is right -- the probe, the leads are part of the measuring device, and they can limit the bandwidth. Let the OP measure another known 14 MHz source with the same probe and oscilloscope.

 

Nonsense - this oscilloscope comes with a 10x probe. But suppose it's lost or the OP doesn’t know how to use the oscilloscope properly - simply popping the chip as I already suggested and measuring pin 10 on the empty socket will settle this. For reference you have Sams' oscillogram on page 57 and mine, which agree within 10%.

Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
There is nothing wrong with

There is nothing wrong with the oscilloscope, the probes, or the person using them—the user knows perfectly well how to operate this equipment. ;) I don’t have another 74S86 chip on hand, but I do have a 74LS86—the result is similar.

As I mentioned earlier, I also took measurements on the PCB with the integrated circuits (including the 74S86) removed. Once the 74S86 was taken out, the result at pin 10 was even worse. I am currently looking for the datasheets for the resonator (NYPH 197-0002) and the 2N4258 transistors.

In my opinion, the issue lies with the 14 MHz signal. While the 7 MHz signal is generated by a 74LS175 chip, the PH0 and PH1 signals are produced using a combination of 74LS175, 74LS153, and 74LS195 chips.

It appears that the 74LS175 works with this non-standard 14 MHz signal, whereas the 74LS195 and 74LS153 chips do not. The fact that the 14 MHz signal does not meet standard TTL parameters does not necessarily mean that the components themselves are faulty.

Unfortunately, I do not have the 14.250025 resonator, and it seems impossible to obtain.

I’ve considered building a similar one using a 14.31818 crystal on a separate PCB to see if everything works.

 

CVT
CVT's picture
Offline
Last seen: 1 day 10 hours ago
Joined: Aug 9 2022 - 00:48
Posts: 1662
gregor wrote:There is nothing
gregor wrote:

There is nothing wrong with the oscilloscope, the probes, or the person using them—the user knows perfectly well how to operate this equipment. ;)

...

 

I myself believe you, but at the same time I can see why others are being skeptical: the sine wave on pin 8 you posted above looks perfect, if one vertical division on the screen corresponds to 10V, instead of 2.5V as you have indicated, since the expected amplitude is supposed to be 4.5V. This is quite a coincident. Of course on pin 10 it's supposed to be 3V, which also agrees with your "even worse" qualification.

Offline
Last seen: 2 hours 16 min ago
Joined: May 31 2022 - 18:18
Posts: 379
gregor wrote:There is nothing
gregor wrote:

There is nothing wrong with the oscilloscope, the probes, or the person using them—the user knows perfectly well how to operate this equipment. ;) I don’t have another 74S86 chip on hand, but I do have a 74LS86—the result is similar.

Just want to point out, while you may know how to use your equipement don't overlook double checking the settings. It's not a critique of you, we've all done it... AC coupling when wanted DC, bandwidth filtering when we didn't want any, etc. Always worthwile to double checking.

 

So just to 2x check... no 1Mhz clock on pin 37 of the 6502?

You walked that back and don't have a 1MHz signal on the output of the S175? Its input should be 2MHz is that present at the flip flop? If not, what's at the input and output of the 153 that's feeding the 175?

 

I feel need to call out the oddness of your scope capture again since we're stuck with your correctly reading and labeling the scope and it's scale. Which... according to your markings has a scale of 2.5V/Division, 5V is one division up, ground is 1 divison down from x-axis.  Ok. But... you've got a 1.25V DC offset which is not good! As you can see in CVT's scope image oscillates between ground and 3V which... would be about right for this circuit although the 86 output should be a bit higher, maybe anohter 10% but likely lower than 80% of Vcc.  So, do you have a 1.25V DC offset on every signal in the system or just at the S86?

 

Good test on the LS86, and assuming you're seeing the same DC offset still not right. If there's a universal DC offset you may have a bad cap /chip or bad AC or DC  ground?  Or even scope/probe ground.

 

Yes, the 7MHz signal comes from a simple clock divider using the 175, should note that's a S175 not LS175, right?

Same with the 195,  S195 not LS195. These need to be sharp fast edges, S should be the spec.

 

One nice thing about this circuit is you have several other similar parts around the board. For example, if you want to check the 153 @C1 pull the 153 that's used for the ROM select somewhere up in rowF. Swap is just temp, just to check the one being used for the clock isn't bad. Similar if you have issues with video, start rotating the 161's and to see if that changes things. Often don't need spares of each part, can often make creative use of other parts in the system. 

Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
This is an original Apple II

This is an original Apple II Europlus, and all the chips are the ones it left the factory with—so wherever there’s supposed to be a 74S-series chip, there is indeed a 74S.I’m thinking of putting together a generator and connecting it externally; I’ll see what the result is.

Offline
Last seen: 2 hours 16 min ago
Joined: May 31 2022 - 18:18
Posts: 379
gregor wrote:This is an
gregor wrote:

This is an original Apple II Europlus, and all the chips are the ones it left the factory with—so wherever there’s supposed to be a 74S-series chip, there is indeed a 74S.I’m thinking of putting together a generator and connecting it externally; I’ll see what the result is.

Thta's good but will  resttae, don't trust any results from "logic tester" should assume everything is bad until it's prooven good. Totally different in-circuit than  simple behavior test. 

 

Can you explian the DC offset? If not, figure that out.  Something is either leaking and rasing ground or maybe supply problem. Gotta start ruling things out. How do all power singals look on the scope? All good and clean? That's a bit of a trick question bc there is no "clean" power on a plus, RFI or not, it's still pretty dirty. 

What's VCC on B2?  Is B2-10 (or 9 whichever isn't ground) good? These logic parts can only drive outputs a percentage of Vcc., and it's not 100%.   

You should also the signal path, you've gone from B2 to B1 for the 175 for the 7MHz which IIRC you said is good. So what about the other path C1->C2->B1?  The B2-8 output fans out all over the borad. Whta often happens with these old boards is there's an internal short on some IC, which can disturb anything else in the circuit. Old parts... are old parts. 

 

Might as well ask because it hasn't been shared yet, can you share  a good image(s) of your borad? May help to understand exactly which borad and compoents you have.

Offline
Last seen: 3 hours 38 min ago
Joined: Jun 18 2010 - 13:54
Posts: 900
jeff d wrote:Can
jeff d wrote:

Can you explian the DC offset?

I attribute the offset to the Vertical Position control!

Offline
Last seen: 1 week 4 days ago
Joined: Jun 11 2025 - 11:24
Posts: 40
 The power supply appears to

 

The power supply appears to be fine. There is some minor noise visible on the GND and Vcc lines on the oscilloscope screen, though you have to look very closely to notice it.The 7 MHz signal is present, but it does not look the way it should.I am almost certain that the oscillator is the source of the problem.A 0.1µF capacitor in the generator was faulty; I replaced it with a 0.1µF ceramic capacitor, but the signal at pin 10 of the 74S86 actually got worse.

 

I’m attaching photos of my PCB, in case that helps.On the other side of the PCB, there’s a capacitor added near the power input; I’m not sure if this is a factory feature or if someone added it later.

Package icon Europlus.zip

 

Offline
Last seen: 2 hours 16 min ago
Joined: May 31 2022 - 18:18
Posts: 379
jeffmazur wrote:jeff d wrote
jeffmazur wrote:
jeff d wrote:

Can you explian the DC offset?

I attribute the offset to the Vertical Position control!

Yah, don't disagree but figure if they markup the scope image gottaa aassume they got that right..... right? 

I has suggested they review all settings becasese who hasn't been confused by strange reading just because settings were different than expecte?

Maybe should just ask for an image of the calibration signal just to confirm scope settings... 

Offline
Last seen: 2 hours 16 min ago
Joined: May 31 2022 - 18:18
Posts: 379
gregor wrote: I’m attaching
gregor wrote:

 

I’m attaching photos of my PCB, in case that helps.On the other side of the PCB, there’s a capacitor added near the power input; I’m not sure if this is a factory feature or if someone added it later.

Is that mat/sheet what you're testing on? If so is it anti-sttaic or in any other way conductive?

 

Your board is the first revision of the RFI II Plus board and looks nice. But I don't recall that "power filter" as a factory modification on the rev1 board. May be, just can't recall ever seeing thta. I'm also assuming, the cap is connected to the contacts for black and orange wires (pins 1 (blaack ground) and 2 (orange 5V)  or 4  (black ground) and 2 when counting as shown in your picture:

1 2 3

4 5 6 

 

Your logic outputs should either be low (0V) or high (5V, but really somewhere around 70-90% Vcc). If not should track down why. If you reserch the 820-0044-01 board and you can't find other examples of the cap on power input it may be worth removing to see if it makes any difference other than noiser 5V line. That said, if it's a factory install it's likley very well done and may not be easy to remove. A 5V power filter wouldn't be a surprise, because do help and power filters were found on the //e with a 10uf electrolytic on all power line inputs.

 

It would also not be unrealistic to add your own 10uf filter between power and ground on the 74LS86 if you want to see if there's a power problem on that chip.